Spectrometer Goniometer SG1800

Spectrometer Goniometer – SG1800

For the precise determination of optical data of prisms

Krüss offers the model SG1800 Spectrometer-Goniometer, for the exact measurement of optical data on prisms. Reflection angle and deflection angle are measurable. From the measured values, for example, the inner angle of a prism or the refractive index of the material used can be determined. It can also be used as a spectroscope, for qualitative examination and measurement of emission and absorption spectra. The observation tube has combined coarse and fine drives, infinitely variable, cross-hairs, eyepiece vernier accuracy. The collimator and the telescope have a focal length of 178mm and a free aperture of 32mm. The Prism offers Flint glass (60deg) with a dispersion angle C-F=2deg. The collimator is a symmetric precision slit of hardened steel. Accessories include prism, Rowland grating and holder, scale illumination, lamp, ocular and spectra sheet.Infinitely adjustable

  • With crosshair eyepiece and vernier reading accuracy of 1angular minute
  • Flint glass prism
  • High-quality collimator made of hardened steel with symmetrical precision gap
  • Extensive accessories

Typical applications

  • For angle measurement on optical components
  • Determination of reflection angle and deflection angle
  • Determination of the inside angle of a prism
  • Determination of the refractive index of the material used

Model specifications

  SG1800
Observation tube infinitely variable
Ocular crosshairs
Scale reading precision 1 angle min.
Objective field number 18, 160 mm focal distance
Prism Flint glass (60°)
Dispersion angle C – F = 2°
Slit tube Symmetric precision slit of hardened steel
Height of the optical axis above the specimen table 0 – 20 mm
Suitable height of the specimen 5 – 50 mm
Focal length collimator 178 mm
Focal length telescope 178 mm
Magnification eyepiece 15x
Free aperture 32 mm
Width entrance slit 0 – 2 mm
Diameter specimen table 85,5 mm
Diameter of the scale 176 mm
Resolution 0°0’30”
Achievable measuring accuracy ± 1’
Scope of delivery Main body incl. collimator, telescope, stage for the specimen 
Prism holder with retaining screws 
Holder for the diffraction grating 
Prisms 
Magnifying glass for the better readability of the scale 
Dust case

Handheld spectroscope
1501

Handheld spectroscope
1504

Spectroscope Kirchhoff-Bunsen
1701