1300 522 725 sales@crealt.com.au
Select Page

High Accuracy Gas Analyser for O2 & COMeasurements

Gas analyser for O2 and CO2 Concentration MAT1500

The all-rounder

Fitted with a zirconium dioxide sensor and a nondispersive infrared sensor, the MAT1500 is our number one when it comes to the range of application, performance and precision. The measurements are completed within only approx. ten seconds. As is the case with the MAT1400,  highly precise results can be achieved with single measurements of oxygen concentrations thanks to the min/max detection even if only a small sample volume is available.

  • Easy and intuitively to use via touch-screen – even by untrained personnel
  • Low-drift zirconium dioxide sensor (ZrO2in the measuring range from 0 to 100 vol.-%
  • Low-drift non-dispersive infrared sensor (NDIR) measures CO2 in the measuring range from 0 to 50 vol.% with an accuracy of ± 0.2 vol.%
  • Short measurement period
  • Only a small sample volume required
  • Interface package for convenient transfer of measured values (USB, Ethernet, RS-232)
  • Any number of measurement methods for the monitoring of the measurement process according to method, batch, product and/or production line incl. limit value monitoring

Typical applications

Because of its excellent accuracy of ±0.001 volume per cent with the lowest O2 concentrations, the MAT1400 with its zirconium dioxide sensor is primarily used to test oxygen free modified atmospheres for sterilised finished products or electronic, pharmaceutical or cosmetic products. Thanks to its wide measurement range between 0 and 100 volume per cent, it can also be used for high oxygen concentrations as required for red fresh meat. The non-dispersive infrared sensor with its wide measurement range between 0 and 50 volume per cent  is suitable for most applications of carbon dioxide in modified atmospheres. Its high accuracy of ±0.5 volume per cent CO2 always ensures precise measurement results. A typical application of the MAT1500 is the control of oxygen and carbon dioxide concentration in the following products:

  • Fresh meat
  • Sausages
  • Raw fish
  • Shellfish and molluscs
  • Poultry
  • Carbonated soft drinks
  • Convenient

A comprehensive overview of typical applications of the gas analyzers of the MAT1000 series can be found in our campus article on gas analyzer applications.

.

Model specifications

MAIN SPECIFICATIONS
SCALES Oxygen 
Carbon dioxide 
Nitrogen 
Any number of user-defined scales
OXYGEN (O2)
MEASUREMENT RANGE 0–100 vol%
ACCURACY ±0.001 vol% (< 1 vol%) 
±0.01 vol% (< 6 vol%) 
±0.1 vol% (< 35 vol%) 
±0.4 vol% (> 35 vol%)
RESOLUTION 0.001 vol%
CARBON DIOXIDE(CO2)
MEASUREMENT RANGE 0–50 vol%
ACCURACY ±0,5 vol%
RESOLUTION 0,1 Vol.-%
NITROGEN (N2)
ARITHMETIC DETERMINATION Residual content of the gas mixture
O2-SENSOR
TYPE Zirconium dioxide sensor ((ZrO2)
MEASUREMENT PRINCIPLE Potentiometric measurement
SERVICE LIFE Unlimited
CROSS-SENSITIVITY Cross-sensitive toward inflammable gases
DRIFT Drift-free
CO2-SENSOR
TYPE Two-channel NDIR sensor
MEASUREMENT PRINCIPLE Infrared spectroscopy
SERVICE LIFE Unlimited
CROSS-SENSITIVITY Not affected by moisture
DRIFT Low drift < 1 %/month

A strong performance package

Digital refractometers with peltier temperature control

Resources & Downloads

Gas analyser MAT1500 Enquiry

For more information or to arrange a call from one of the Cea Analytical Team, please complete the contact form below.  If your enquiry is urgent, please call us on 1300 552 725.

Gas analyser MAT1500 Enquiry

NATIONAL OFFICE

EMAIL

sales@crealt.com.au

accounts@crealt.com.au

service@crealt.com.au

GET SOCIAL

PHONE

NSW: +61 2 4320 6672

VIC: +61 3 9017 4496

QLD: +61 7 3333 2171

WA: +61 8 6465 4576

NZ: +64 212 372 731

CONTACT US