High Accuracy Gas Analyser for O2 Measurements

Gas analyser for highly accurate O2 measurements MAT1400

For high O2 concentrations and high sample volume

The zirconium dioxide sensor (ZrO2) of the MAT1400 measures the oxygen concentration over the entire measurement range between 0 and 100 volume per cent. Especially in case of a very low concentration, it will achieve an excellent accuracy of ±0.001 volume per cent. The MAT1400 is therefore suitable for the inspection of oxygen-free as well as oxygen-rich modified atmospheres. It can also be used in the cold storage room from ambient temperatures of 10 °C.

  • Easy and intuitively to use via touch-screen – even by untrained personnel
  • Low-drift zirconium dioxide sensor (ZrO2in the measuring range from 0 to 100 vol.-%
  • Short measurement period
  • Only a small sample volume required
  • Interface package for convenient transfer of measured values (USB, Ethernet, RS-232)
  • Any number of measurement methods for the monitoring of the measurement process according to method, batch, product and/or production line incl. limit value monitoring

Typical applications

Because of its excellent accuracy of ±0.001 volume per cent with the lowest O2 concentrations, the MAT1400 with its zirconium dioxide sensor is primarily used to test oxygen free modified atmospheres for sterilised finished products or electronic, pharmaceutical or cosmetic products. Thanks to its wide measurement range between 0 and 100 volume per cent, it can also be used for high oxygen concentrations as required for red fresh meat. The investment in the zirconium dioxide sensor will quickly pay off if many samples are measured every day due to the long service life of up to 15 years. Thanks to the fast response time of 0.3 seconds, only very little sample gas is required – an advantage especially in case of a small headspace volume as it is common with sachets and cosmetics products. The cross-sensitivity of the sensor toward humidity and temperature is low. A regular adjustment is not necessary because it is free of drift. Typical applications are the control of oxygen concentration in particularly oxygen-sensitive and sterilized products and products with high oxygen concentration, such as:

  • Fresh meat
  • Sausages
  • Dried foods
  • Milk powder
  • Fruit juices
  • Yogurt and dairy products

A comprehensive overview of typical applications of the gas analyzers of the MAT1000 series can be found in our campus article on gas analyzer applications.

Model specifications

  MAT1400
MAIN SPECIFICATIONS
SCALES Oxygen 
Any number of user-defined scales
OXYGEN (O2)
MEASUREMENT RANGE 0–100 vol%
ACCURACY ±0.001 vol% (< 1 vol%) 
±0.01 vol% (< 6 vol%) 
±0.1 vol% (< 35 vol%) 
±0.4 vol% (> 35 vol%)
RESOLUTION 0.001 vol%
O2-SENSOR
TYPE Zirconium dioxide sensor (ZrO2)
MEASUREMENT PRINCIPLE Potentiometric measurement
SERVICE LIFE Unlimited
CROSS-SENSITIVITY Cross-sensitive toward inflammable gases
DRIFT Drift-free

Digital refractometers with peltier temperature control

Resources & Downloads

Gas analyser MAT1400 Enquiry

For more information or to arrange a call from one of the Cea Analytical Team, please complete the contact form below.  If your enquiry is urgent, please call us on 1300 552 725.

Gas analyser MAT1400 Enquiry

NATIONAL OFFICE

EMAIL

sales@crealt.com.au

accounts@crealt.com.au

service@crealt.com.au

GET SOCIAL

PHONE

NSW: +61 2 4320 6672

VIC: +61 3 9017 4496

QLD: +61 7 3333 2171

WA: +61 8 6465 4576

NZ: +64 212 372 731

CONTACT US