DR6000-T

Digital refractometers with peltier temperature control
Powerful all-rounder: the DR6000-T
As a standard, the refractometer models DR6000-T and DR6000-TF are equipped with a Peltier element that controls the temperature of the sample up to 80 °C. There are four different models available for different requirements on accuracy, resolution and measurement range whereby you can access the same operation and functionality.
Measurement of turbid or highly viscous samples
With highly accurate internal Peltier temperature control
Preinstalled and freely definable scales with conversions based on tables or formulas
Chemical-resistant materials such as measurement prism made of sapphire, measuring tray made of stainless steel
Intuitive operation via touch-screen display
Complete data recording and backup including audit trail
Flexible data export
Compliance with global standards and norms
Typical applications
The DR6000-T models are the ideal solution for the pharmaceutical, chemical, food and beverage industries, flavors, fragrance and essential oil, petrochemical, metalworking and automotive industries, as well as hospitals, pharmacies and exam offices.
Characterisation tests in research and development
Identity test, purity control and concentration determination of raw materials, semi-finished products and end products
Tracking of chemical processes during production
Stability test
Determination of the sugar concentration in semi-finished products and end products
Determination of the solids content in solutions
Determination of the purity in combination with a polarimeter
Monitoring of the production of semi-finished products and end products
Routine analysis with high sample throughput
Determination of the sugar concentration in juices and alcohol-free beverages
Determination of the alcohol or extract content in beer, spices, wine or spirits
Sewage water check
Incoming and outgoing goods inspection
Checking medicines for pharmacopeias
Analysis of body secretions
Testing of the compliance with national and international standards
For a comprehensive overview of typical applications using the DR6000 Series of Digital Refractometers, visit our campus review Refractometer applications.
Conformity with national and international standards
A big advantage of normalized measurements is the comparability of the measurement results. Refractometers for specific measuring tasks are recommended as suitable measuring instruments in many international standards and guidelines. The requirements for the measuring devices, such as measuring accuracy and measuring temperature, are dependent on the respective measuring task and defined in each standard. We have compiled for you an overview of all known standards and guidelines, which refer to the refractometry.
Association of Analytical Communities (AOAC)
American Oil Chemists’ Society (AOCS)
American Society for Testing and Materials (ASTM)
German Institute for Standardization (DIN)
International Organization of Legal Metrology (OIML)
International Organization of Vine and Wine (OIV)
International Commission for Uniform Methods of Sugar Analysis (ICUMSA)
International Organization for Standardization (ISO)
United States Pharmacopeial (USP)
European Pharmacopoeia (Ph. Eur.)
European Honey Commission (EHC)
Refractometer standards (PDF, 106 KB)
Any questions?
Get in contact with us, we will assist you in choosing the right refractometer for you.
All samples are measurable
From bright to dark, from basic to acidic, from a low to a high viscosity – for our refractometers almost all samples are measurable. A high-quality optics, intelligent evaluation logarithms and a powerful LED enable the measurement of particularly challenging samples. These include z. For example, non-homogeneous samples such as fruit juices containing pulp, opaque samples such as heavy oils or emulsions that are common in cosmetics. Aggressive acids and bases can be easily measured using a chemical-resistant stainless steel measuring tray and a sapphire prism.Even foils and solids can be measured by using a high-refractive contact liquid.
In order to serve the existing variety of samples and the wide range of applications, we offer a wide range of different refractometers. For the selection of the suitable refractometer, it is helpful to define the required measuring range.
In the following table we have compiled an overview of typical samples from our customers and sorted them by refractive index. Most samples were measured at standard measurement conditions (20 ° C, λ = 589 nm), deviations are indicated. The measurements given are not specifications.
Refractometer samples (PDF, 196 KB)
Any questions?
Get in contact with us, we will assist you in choosing a suitable refractometer.
Model specifications
| DR6000-T | DR6100-T | DR6200-T | DR6300-T | |
|---|---|---|---|---|
| MEASUREMENT DATA | ||||
| SCALES | Refractive index (nD) Concentration of sucrose, glucose, fructose and invert sugar [%Brix], User-defined | |||
| MEASUREMENT RANGE | nD 1.3200–1.5800 0–95 %Brix | nD 1.3200–1.7000 0–95 %Brix | nD 1.32000–1.58000 0–95 %Brix | nD 1.32000–1.70000 0–95 %Brix |
| MEASUREMENT ACCURACY | nD ±0.0001 ±0.1 %Brix | nD ±0.00002 ±0.02 %Brix | ||
| RESOLUTION | nD 0.0001 0.1 %Brix | nD 0.00001 0.01 %Brix | ||
| MEASUREMENT PERIOD | approx. 4 s | |||
| MEASUREMENT PRISM | Sapphire | |||
| LIGHT SOURCE | LED | |||
| WAVELENGTH | 589 nm | |||
| TEMPERATURE DATA | ||||
| TEMPERATURE CONTROL | With integrated Peltier temperature control | |||
| TEMP. CONTROL RANGE | 10–80 °C | |||
| ACCURACY OF TEMP. CONTROL | ±0.1 °C | |||
| TEMPERATURE COMPENSATION | Can be activated (ICUMSA or freely definable) | |||
| TEMPERATURE MEASUREMENT | With integrated temperature sensor Pt100 | |||
| TEMPERATURE MEASUREMENT RANGE | 10–80 °C | |||
| TEMP. MEASUREMENT ACCURACY | ±0.1 °C | |||
| TEMP. MEASUREMENT RESOLUTION | 0.1 °C | |||
Digital refractometers with peltier temperature control
For more information or to arrange a call from one of the Cea Analytical Team, please complete the contact form below. If your enquiry is urgent, please call us on 1300 552 725.
DR6000 T Enquiry
NATIONAL OFFICE
Crea Laboratory Technologies
U4/4 Teamster Close
PO Box 3791
TUGGERAH NSW 2259
T: +61 2 4320 6670
GET SOCIAL
TERMS & CONDITIONS
PHONE
NSW: +61 2 4320 6672
VIC: +61 3 9017 4496
QLD: +61 7 3333 2171
WA: +61 8 6465 4576
NZ: +64 212 372 731